Clinically Relevant Solutions

Optimizing Patient Care

NKV-550 Series Ventilator System

The NKV-550 Series Ventilator System is a comprehensive neonatal through adult mechanical ventilator.

It features an intuitive and customizable app-based platform providing clinicians with the tools to individualize lung protective strategies. The ability to transition patients between invasive, non-invasive ventilation and high-flow oxygen therapy with one device reduces hospital costs and clinician's time.

Key Features

*Regionally available for purchase

Key Features

Adult, pediatric and neonates (tidal volumes ≥ 2 ml)

Seamlessly transition from invasive ventilation, non-invasive ventilation, high flow oxygen therapy.

Hot-Swappable Extended Battery.

Protective Control- Secondary Graphic User Interface to minimize clinician's exposure to biological and radiologic hazards.

Comprehensive monitoring: SpO₂, Volumetric Capnography, End-tidal CO₂, P0.1. Transpulmonary Pressure.

Modern, intuitive, and customizable, App-based user interface.

Gentle Lung® guided steps for Recruitability Assessment, Recruitment Maneuver, and PEEP-Titration.

Innovative mode of ventilation *AVM (Adaptive Ventilation Mode) helps clinicians monitor and transition patients between mandatory and spontaneous states by auto-adapts to patient respiratory status.

*AdaptiveSync™  helps alleviate patient-ventilator asynchrony with AdaptiveTrigger™  and AdaptiveCycle™ .

Series

Features
       NKV-550-N (Neonatal)
       NKV-550-S (Standard)
       NKV-550-U (Universal)

Patient Type

Neonatal

Pediatric

Adult

Neonatal Flow Sensor Port

Not available in the US

Nihon Kohden SpO₂ and CO₂ Port

Nihon Kohden SpO₂ and CO₂ Kit

Cable and Sensors

Aerogen Nebulizer Support

Hot-Swappable Extended Battery

Gentle Lung® Suite

--

Adaptive Ventilation Mode

Regionally Available

--

AdaptiveSync™

Regionally Available

--

Available

- - Not available

* Available for purchase

Modes

Invasive
A/CMV

PC, VC, PRVC

SIMV

PC-PS, VC-PS, PRVC-PS, PS

SPONT

CPAP, PS, VS, APRV

ADAPTIVE

AVM*

Non-Invasive
A/CMV

PC

SIMV

PC-PS

SPONT

CPAP, PS, APRV

High flow oxygen

*Regionally available for purchase, contact the local Nihon Kohden's representative for availability.

Specifications

Tidal Volume

2 to 100 mL Neonate

20 to 1000 mL Pediatric

100 to 3000 mL Adult

Power

100 - 240V 50/60 Hz A/C

50-minute internal battery*

130-minute hot-swappable extended battery*

*New and fully charged battery at standard settings

Connectivity

Physiologic monitor (2)

Neonatal flow sensor port (1)

USB port (2)

Nurse Call (1)

RS-232 (1)

Applications and Maneuvers
  • NIF/PiMax maneuver
  • P0.1 measurement
  • Low-flow PV maneuver
  • Volumetric Capnography
  • Spontaneous breathing trial
  • Video and screen capture
  • Key Features
  • Series
  • Modes
  • Specifications
Key Features

*Regionally available for purchase

Key Features

Adult, pediatric and neonates (tidal volumes ≥ 2 ml)

Seamlessly transition from invasive ventilation, non-invasive ventilation, high flow oxygen therapy.

Hot-Swappable Extended Battery.

Protective Control- Secondary Graphic User Interface to minimize clinician's exposure to biological and radiologic hazards.

Comprehensive monitoring: SpO₂, Volumetric Capnography, End-tidal CO₂, P0.1. Transpulmonary Pressure.

Modern, intuitive, and customizable, App-based user interface.

Gentle Lung® guided steps for Recruitability Assessment, Recruitment Maneuver, and PEEP-Titration.

Innovative mode of ventilation *AVM (Adaptive Ventilation Mode) helps clinicians monitor and transition patients between mandatory and spontaneous states by auto-adapts to patient respiratory status.

*AdaptiveSync™ helps alleviate patient-ventilator asynchrony with AdaptiveTrigger™ and AdaptiveCycle™ .

Series
Features
       NKV-550-N (Neonatal)
       NKV-550-S (Standard)
       NKV-550-U (Universal)

Patient Type

Neonatal

Pediatric

Adult

Neonatal Flow Sensor Port

Not available in the US

Nihon Kohden SpO₂ and CO₂ Port

Nihon Kohden SpO₂ and CO₂ Kit

Cable and Sensors

Aerogen Nebulizer Support

Hot-Swappable Extended Battery

Gentle Lung® Suite

--

Adaptive Ventilation Mode

Regionally Available

--

AdaptiveSync™

Regionally Available

--

Available

- - Not available

* Available for purchase

Modes
Invasive
A/CMV

PC, VC, PRVC

SIMV

PC-PS, VC-PS, PRVC-PS, PS

SPONT

CPAP, PS, VS, APRV

ADAPTIVE

AVM*

Non-Invasive
A/CMV

PC

SIMV

PC-PS

SPONT

CPAP, PS, APRV

High flow oxygen

*Regionally available for purchase, contact the local Nihon Kohden's representative for availability.

Specifications
Tidal Volume

2 to 100 mL Neonate

20 to 1000 mL Pediatric

100 to 3000 mL Adult

Power

100 - 240V 50/60 Hz A/C

50-minute internal battery*

130-minute hot-swappable extended battery*

*New and fully charged battery at standard settings

Connectivity

Physiologic monitor (2)

Neonatal flow sensor port (1)

USB port (2)

Nurse Call (1)

RS-232 (1)

Applications and Maneuvers
  • NIF/PiMax maneuver
  • P0.1 measurement
  • Low-flow PV maneuver
  • Volumetric Capnography
  • Spontaneous breathing trial
  • Video and screen capture

Key Features

Seamlessly transition patients between invasive, non-invasive ventilation, and high flow oxygen therapy.

Hot-swappable extended battery.

HEPA filtered, high-performance internal turbine.

Integrated pneumatic nebulizer and Aerogen nebulizer support.

Comprehensive Monitoring: SpO2, CO2, P0.1, Volumetric Capnography.

Modern, intuitive, and customizable, application-based (App) user interface.

Gentle Lung: guided steps for Recruitability Assessment, Recruitment Maneuver and PEEP-Titration.

Neonatal

Pediatric

Adult

Intuitive, Customizable, App-Based Graphic User Interface

Our App-based design provides guided processes to help create a more streamlined, systematic way for clinicians to optimize the care of their ventilated patients. This interface makes it easy to add features or customize the layout to fit into your workflow. Your nine favorite apps are always available, and the remainder are a click away.

Comprehensive Monitoring

Pulse Oximetry

Volumetric Capnography

Transpulmonary Pressure

Auxiliary Pressure

Second Graphic User Interface

Protective Control® provides the clinician a safe, fully functional second user interface to easily implement needed ventilator setting changes when treating patients with contagious diseases while remaining within sight of the clinician.

Individualized Patient Care

AdaptiveSync™ provides multi-level trigger and cycle to meet the patient's respiratory demands.

AdaptiveTrigger™

AdaptiveCycle™

Trolleys

Mobility

Trolley with built-in-shelf.

Compact trolley

Medical Air Compressor trolley

Medical Air Compressor is beautifully integrated within the NKV-550 trolley, the AIR-550's near vibration-free design allows for quiet operation in any hospital settings from the adult to neonatal ICU.

Lung Protection Tools

Gentle Lung® Suite

Recruitability Assessment

Provides clinician insight into patient's lungs to help determine if a recruitment maneuver could be beneficial.

Recruitment Maneuver

Customized stepwise lung recruitment maneuvers enable clinicians to focus on the patient's condition.

PEEP Titration

Continuation of recruitment maneuver or independently initiated to help determine PEEP at best compliance.

Transpulmonary Pressure App

The Transpulmonary Pressure App monitors the transpulmonary pressure to help individualize a lung protective treatment strategy.

Lung Protection Tools

Adaptive Ventilation Mode* (AVM)

An optional tool, allowing the ventilator to auto-adapt to the patient's respiratory status.

Smoothly auto-transform the patient between full ventilatory support and spontaneous ventilation as set by the clinicians.

Automatically monitor the patient's respiratory status to either wean or escalate ventilatory support, while limiting driving pressure for

lung protection.

*Regionally available for purchase, contact the local Nihon Kohden's representative for availability.

Gentle Lung® Suite

Recruitability Assessment

Provides clinician insight into patient's lungs to help determine if a recruitment maneuver could be beneficial.

Recruitment Maneuver

Customized stepwise lung recruitment maneuvers enable clinicians to focus on the patient's condition.

PEEP Titration

Continuation of recruitment maneuver or independently initiated to help determine PEEP at best compliance.

Transpulmonary Pressure App

The Transpulmonary Pressure App monitors the transpulmonary pressure to help individualize a lung protective treatment strategy.

Connectivity

The NKV-550 Ventilator is compatible with the following data management platforms:

Nihon Kohden bedside monitors

GE Healthcare bedside monitors

Phillips bedside monitors

Data Management Systems

Nihon Kohden Ventilator Gateway

Capsule Technologies

Cerner CareAware iBus

CliniComp EHR

GE Unity Network ID

IMDsoft

Masimo

Picis

© 2026 All Rights Reserved | OrangeMed