NKV-440 Ventilator System

Ventilator System

Ventilator System

Key Features

Seamlessly transition patients between invasive, non-invasive ventilation, and high flow oxygen therapy.

Hot-swappable extended battery

HEPA filtered, high-performance internal turbine.

Integrated pneumatic nebulizer and Aerogen nebulizer support.

Comprehensive Monitoring: SpO2, CO2, P0.1, Volumetric Capnography.

Modern, intuitive, and customizable, application-based (App) user interface.

Gentle Lung®: guided steps for Recruitability Assessment, Recruitment Maneuver and PEEP-Titration.

Modes

Invasive

A/CMV

PC, VC, PRVC

SIMV

PC-PS, VC-PS, PRVC-PS

SPONT

CPAP, PS, VS, APRV

Non-Invasive

A/CMV

PC

SIMV

PC-PS

SPONT

CPAP, PS, APRV

High flow oxygen therapy

Specifications

Communication

  • RS-232 (1):Data integration
  • DH60 (1):Respiratory phase signal
  • USB (2):Download data, software
  • upgrade, import/export configurations.

Physical

  • Height (display up):19.9 in. (50.6 cm)
  • Height (display down):9.9 in. (25.1 cm)
  • Width:12.1 in. (30.8 cm)
  • Depth:16.4 in. (41.7 cm)
  • Weight:22.3 lb. (10.1 kg)

Intuitive, Customizable, App-based Graphic User Interface

Monitoring layout such as waveforms, loops and App panel are customizable.

INTEGRATED PNEUMATIC NEBULIZER

INTEGRATED PNEUMATIC NEBULIZER

Built-in pneumatic nebulizer support eliminates the need for external flow and allows the clinician to choose the respiratory phase desired for the delivery of traditional aerosol particles.

SpO<sub>2 </sub>and CO<sub>2</sub> MONITORING

SpO2 and CO2 MONITORING

Able to monitor CO2 and SpO2 during invasive
and non-invasive ventilation with Nihon Kohden’s
ultra-compact cap-ONE CO2 sensor and SpO2 sensor.

HOT-SWAPPABLE EXTENDED

HOT-SWAPPABLE EXTENDED

The built-in batteries support 5 hours of operation under the tested conditions, and multiple hot-swappable batteries offer even more hours.
HEPA-FILTERED INTERNAL TURBINE

HEPA-FILTERED INTERNAL TURBINE

Equipped with HEPA filter, the high-performance turbine provides filtered air to the patients.
ENHANCED MOBILITY

ENHANCED MOBILITY

TROLLEY

TROLLEY

Trolley with dual oxygen cylinder holder.

LUNG PROTECTION TOOLS

RECRUITABILITY ASSESSMENT

RECRUITABILITY ASSESSMENT

Provides clinician insight into patient’s lungs to help determine if a recruitment maneuver could be beneficial.
RECRUITMENT MANEUVER

RECRUITMENT MANEUVER

Customized stepwise lung recruitment maneuvers enable clinicians to focus on the patient’s condition.
PEEP TITRATION

PEEP TITRATION

Continuation of recruitment maneuver or independently initiated to help determine PEEP at best compliance. link

Get Connected

NKV-440 ventilator is compatible with the following data management platforms:

Nihon Kohden bedside monitors

Nihon Kohden bedside monitors

GE Healthcare bedside monitors

GE Healthcare bedside monitors

Phillips bedside monitors

Phillips bedside monitors